Connect Adlumin
Adlumin is N-able's managed detection and response (MDR) and XDR platform. StackJack connects an AI assistant to the Adlumin customer data API of one Adlumin tenant.
Written By Christopher Scaminaci
Last updated 1 day ago
Adlumin is N-able's managed detection and response (MDR) and XDR platform. StackJack connects an AI assistant to the Adlumin customer data API of one Adlumin tenant.
Connecting Adlumin to StackJack gives your AI assistant a family of adlumin_ MCP tools. MCP (Model Context Protocol) tools are the standardized commands an AI
assistant can call through StackJack. With them, your AI can:
- Read detections - list the detections of the tenant, or find one by id, date range, status or text
- Read accounts and sensors - Active Directory accounts by name, and the health of each sensor
- Read at-risk assets - the Active Directory groups, network shares and systems Adlumin flags
- Read compliance counts - stale accounts, stale passwords, passwords that never expire, reversible encryption and group policy violations
- Read security events - raw endpoint, device, firewall and network events
- Work a detection (on Pro plans) - acknowledge it, add a note to it, and set its status
How StackJack authenticates to Adlumin
Adlumin takes an API key and the id of the Adlumin tenant the key belongs to. StackJack sends the key in the x-api-key header and the tenant id with every
call. There is no sign-in exchange: the key is used as it is.
Getting the key and the tenant id
Ask your Adlumin platform admin for an API key of the tenant you want to connect, and for the tenant id. N-able does not publish where in Adlumin a key is made.
The key and the tenant id must belong together. Adlumin refuses a key on another tenant's id.
One connection is one tenant
A connection reads and changes one Adlumin tenant. If you work with several tenants, add one named connection for each. Every tool also takes a tenant id for one call, which replaces the saved one. It works only when Adlumin accepts your key for that tenant.
Connect it in StackJack
- Open Connectors, then Adlumin.
- Enter the Adlumin tenant ID.
- Paste the API key.
- Click Save. StackJack stores the connection and then checks it: it reads the five compliance counts, which changes nothing.
To check a saved connection again later, use Test on its row. The test uses the key that is saved, so save a new key before you test it.
Enter both values again whenever you save this form. To rename a connection, use Rename in the connections list: a rename needs no key.
What is worth knowing before you start
An empty result is not an error
When nothing matches, Adlumin answers {"failed": "No records found"} or {"failed": "Account not found"}. StackJack returns that answer unchanged. It means an
empty list.
Detections have no pages
Adlumin returns every matching detection in one answer. Give a date range, a status or a search text, so the answer stays small. The event reads have pages: send the
scroll_id of one answer to get the next one. There is no page size.
Changes that are marked destructive
These tools are Pro:
- Acknowledge a detection - marks one detection acknowledged. There is no bulk form.
- Set a detection's status - the new status is
awaiting investigation,in progress,cleared,incident declaredorwhitelist.
StackJack marks these tools as destructive. Whether your AI application asks for confirmation depends on its settings: some clients prompt before every tool call, some prompt only for tools the server marked destructive, some remember an earlier "always allow", and some never prompt. Review those settings, and leave out the tools a connection does not need. How tools work has the details.
Adding a note to a detection is Pro and is not marked destructive. The note carries the author's email address you give.
StackJack never sends a change twice. When Adlumin does not confirm a change, the tool says so: read the detection before you try again.
Rate limit
Adlumin documents no rate limit. StackJack paces one connection at about one call a second and waits when Adlumin answers that there are too many requests.
When Adlumin refuses a call
- The key and the tenant do not belong together (401 or 403): check the tenant id on the connection, or the tenant id you passed. If the pair is right, ask for a new API key.
- Something else answered: a gateway, a proxy or a firewall replied instead of Adlumin. The key was not judged. Try again later.
- A bad request (400): Adlumin refuses a missing or malformed date, id or scroll id. Dates are ISO 8601 (
2026-06-01). - Not found (404): check the detection id.
- Too many requests (429): wait before you try again.
- An outage (5xx): wait and try again.
Plans and limits
Every read is available on the Free tier. Every change is Pro. Business reaches the same tools as Pro and differs by monthly call quota.
See the generated Adlumin tool reference for the current inventory, plan assignment, input schemas and destructive-action labels.
Adlumin tools
adlumin_ · 16 tools · Free 13 · Pro 3
Detections
Accounts and sensor health
At-risk assets
Compliance
Security events
Service status
Was this helpful?
More in Connector guides
Connect 3CXConnect AbleSignConnect Acronis Cyber Protect CloudConnect Action1Still need help? Ask the team